This chart is applicable for designing compressed air systems. The flow values in this chart are based on a pressure drop as set forth in the following schedule:

Pressure Drop per 100 Feet of Pipe
                                 Pipe Size - Inches
10% of Applied Pressure                                                1/8, 1/4, 3/8, 1/2
5% of Applied Pressure                                                  3/4 & 1

Nominal Standard Pipe Size - Inch

Derived Units = Pressure Drop per 100 Feet of Pipe (SCFM)

Applied Pressure
psig
1/8 1/4 3/8 1/2 3/4 1
5 0.5 1.2 2.7 4.9 6.6 13
10 0.8 1.7 3.9 7.7 11.0 21
20 1.3 3.0 6.6 13.0 18.5 35
40 2.5 5.5 12.0 23.0 34.0 62
60 3.5 8.0 18.0 34.0 50.0 93
80 4.7 10.5 23.0 44.0 65.0 120
100 5.8 13.0 29.0 54.0 80.0 150
150 8.6 20.0 41.0 80.0 115.0 220
200 11.5 26.0 58.0 108.0 155.0 290
250 14.5 33.0 73.0 135.0 200.0 370